DocumentCode
345562
Title
Development of high power gridded tube CW RF systems with excellent reliability and maintainability
Author
Cherix, J. ; Maerki, M. ; Fitze, H-R. ; Frei, H. ; Sigg, P.K.
Author_Institution
PSI, Villigen, Switzerland
Volume
1
fYear
1999
fDate
1999
Firstpage
418
Abstract
In the course of expanding the PSI proton accelerator complex towards very high beam currents, the entire RF system (except cavities) was redesigned. Aside from the set beam intensity goal, higher reliability became a prime objective. Analysing problem areas and failure mechanisms led to a much improved overall system. New power amplifiers and coupling loops were designed, together with improved protection, spark detection and RF recovery systems. This paper shows and explains the recently obtained results in performance and discusses means for further improvements
Keywords
accelerator RF systems; microwave power amplifiers; proton accelerators; reliability; storage rings; PSI; RF system; coupling loops; failure mechanisms; gridded tube CW RF systems; maintainability; power amplifiers; proton accelerator; reliability; Control systems; Cyclotrons; Failure analysis; Maintenance; Particle accelerators; Particle beams; Power amplifiers; Power system reliability; Radio frequency; Radiofrequency amplifiers;
fLanguage
English