DocumentCode
3455886
Title
Time transfer using an asynchronous computer network: An analysis of error sources
Author
Ebenhag, S.C. ; Jarlemark, P. ; Hedekvist, P.O. ; Emardson, R.
Author_Institution
SP Tech. Res. Inst. of Sweden, Boras
fYear
2007
fDate
May 29 2007-June 1 2007
Firstpage
827
Lastpage
831
Abstract
We have performed a time transfer over a distance of approximately 75 km using an asynchronous computer network based on optical fibers. In order to validate the results from this fiber-link, we have compared the results with a GPS-link, which consists of carrier phase observations. All electronic cabinets were equipped with temperature and humidity sensors. Here we present experiments where the temperature and humidity of the delay in the electrical components were investigated. All components showed some temperature dependence, but no significant humidity dependence was found. By using the derived temperature coefficient for the components the standard deviation of the difference between the fiber link and GPS link decreased from 243 ps to 184 ps.
Keywords
computer networks; humidity sensors; optical fibres; oscillators; temperature sensors; GPS-link; asynchronous computer network; carrier phase observations; electronic cabinets; error sources; fiber link; humidity sensors; optical fibers; temperature sensors; time transfer; Computer errors; Computer networks; Delay; Error analysis; Global Positioning System; Humidity; Optical fiber sensors; Optical fibers; Temperature dependence; Temperature sensors;
fLanguage
English
Publisher
ieee
Conference_Titel
Frequency Control Symposium, 2007 Joint with the 21st European Frequency and Time Forum. IEEE International
Conference_Location
Geneva
ISSN
1075-6787
Print_ISBN
978-1-4244-0646-3
Electronic_ISBN
1075-6787
Type
conf
DOI
10.1109/FREQ.2007.4319192
Filename
4319192
Link To Document