• DocumentCode
    3457207
  • Title

    Large volume threshold Cerenkov counters

  • Author

    Kawall, D. ; Meziani, Z.E. ; Gearhart, R.A.

  • Author_Institution
    Dept. of Phys., Stanford Univ., CA, USA
  • fYear
    1991
  • fDate
    2-9 Nov. 1991
  • Firstpage
    422
  • Abstract
    The authors summarize the design of a set of large-volume gas threshold Cerenkov counters to be used in the fixed target experiment E142 at the Stanford Linear Accelerator Center (SLAC). The counters are designed to operate at a pion threshold of 13 GeV/c and will use a 4.0-m effective length of CO/sub 2/ at 0.136-atm pressure as a radiator. A 5-in photomultiplier will be used to detect an expected average of 6.5 photoelectrons per electron scattered through the counter.<>
  • Keywords
    Cherenkov counters; electron detection and measurement; 0.136 atm; 4 m; 5 in; CO/sub 2/; fixed target experiment; large-volume gas threshold Cerenkov counters; photoelectrons; Counting circuits; Electromagnetic scattering; Electrons; Mesons; Optical refraction; Particle scattering; Photomultipliers; Physics; Spectroscopy; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
  • Conference_Location
    Santa Fe, NM, USA
  • Print_ISBN
    0-7803-0513-2
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1991.258944
  • Filename
    258944