DocumentCode :
3458412
Title :
Optimal operation of contactless transformers with resonance in secondary circuits
Author :
Xun Liu ; Ng, W.M. ; Lee, Chi Kwan ; Hui, S.Y.
Author_Institution :
ConvenientPower Ltd., Hong Kong
fYear :
2008
fDate :
24-28 Feb. 2008
Firstpage :
645
Lastpage :
650
Abstract :
Contactless transformer is an essential element in inductive power transfer systems. To improve its efficiency performance, a resonant tank is normally formed at the secondary side by adding an external capacitor in series (SS) or in parallel (SP) with the secondary winding. In this paper, a mathematical analysis based on simplified circuit model is presented. It leads to the theory of the boundary frequency which can be used to determine the optimal operating range for SS and SP mode, respectively, from the efficiency point of view. Calculated and measured results have been given to verify the theory in a case study.
Keywords :
mathematical analysis; transformer windings; boundary frequency theory; contactless transformers; inductive power transfer systems; mathematical analysis; resonant tank; secondary circuits; secondary winding; Capacitors; Contacts; Equivalent circuits; Impedance; Mathematical analysis; Mathematical model; RLC circuits; Resonance; Transformers; Zirconium; contactless transformer; efficiency; resonance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference and Exposition, 2008. APEC 2008. Twenty-Third Annual IEEE
Conference_Location :
Austin, TX
ISSN :
1048-2334
Print_ISBN :
978-1-4244-1873-2
Type :
conf
DOI :
10.1109/APEC.2008.4522790
Filename :
4522790
Link To Document :