Title :
Optimal operation of contactless transformers with resonance in secondary circuits
Author :
Xun Liu ; Ng, W.M. ; Lee, Chi Kwan ; Hui, S.Y.
Author_Institution :
ConvenientPower Ltd., Hong Kong
Abstract :
Contactless transformer is an essential element in inductive power transfer systems. To improve its efficiency performance, a resonant tank is normally formed at the secondary side by adding an external capacitor in series (SS) or in parallel (SP) with the secondary winding. In this paper, a mathematical analysis based on simplified circuit model is presented. It leads to the theory of the boundary frequency which can be used to determine the optimal operating range for SS and SP mode, respectively, from the efficiency point of view. Calculated and measured results have been given to verify the theory in a case study.
Keywords :
mathematical analysis; transformer windings; boundary frequency theory; contactless transformers; inductive power transfer systems; mathematical analysis; resonant tank; secondary circuits; secondary winding; Capacitors; Contacts; Equivalent circuits; Impedance; Mathematical analysis; Mathematical model; RLC circuits; Resonance; Transformers; Zirconium; contactless transformer; efficiency; resonance;
Conference_Titel :
Applied Power Electronics Conference and Exposition, 2008. APEC 2008. Twenty-Third Annual IEEE
Conference_Location :
Austin, TX
Print_ISBN :
978-1-4244-1873-2
DOI :
10.1109/APEC.2008.4522790