DocumentCode :
3458935
Title :
Inverter power drive transistor diagnostic and extended operation under one-transistor trigger suppression
Author :
Ginart, Antonio ; Brown, Douglas ; Kalgren, Patrick ; Roemer, Michael J.
Author_Institution :
Impact Technol., LLC, Atlanta, GA
fYear :
2008
fDate :
24-28 Feb. 2008
Firstpage :
873
Lastpage :
878
Abstract :
A fault-accommodation technique proposed for inverter drive systems extends the operation of an electrical power drive during an incipient power transistor fault. The discussed technique utilizes diagnostic methods to identify and isolate degraded power transistors. Once isolated, a suitable fault-accommodating control method using one-transistor trigger suppression (OTTS) control relieves electrical overstress applied to the degraded transistor to maintain operation of the motor while avoiding an inverter failure. Feasibility of the proposed method is demonstrated using V/f and vector techniques with an additional external fuzzy control for startup and steady-state conditions. Also discussed are advantages and potential drawbacks of this technique.
Keywords :
AC motor drives; fault diagnosis; fuzzy control; invertors; machine control; power transistors; degraded power transistors; electrical overstress; electrical power drive; external fuzzy control; fault-accommodating control method; fault-accommodation technique; inverter failure; inverter power drive; one-transistor trigger suppression; power transistor fault; Inverters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference and Exposition, 2008. APEC 2008. Twenty-Third Annual IEEE
Conference_Location :
Austin, TX
ISSN :
1048-2334
Print_ISBN :
978-1-4244-1873-2
Electronic_ISBN :
1048-2334
Type :
conf
DOI :
10.1109/APEC.2008.4522823
Filename :
4522823
Link To Document :