DocumentCode
3459416
Title
Identifying isometric recruitment curves of electrically stimulated muscle
Author
Durfee, W.K. ; MacLean, K.E.
Author_Institution
Dept. of Mech. Eng., MIT, Cambridge, MA, USA
fYear
1988
fDate
4-7 Nov. 1988
Firstpage
1658
Abstract
Two methods for estimating isometric recruitment curves of electrically stimulated muscles were tested on isolated muscles of anesthetized cats. The new, ramp deconvolution method results in estimates similar to the more traditional step response method but offers a higher resolution curve in less time. Changes in threshold and of the isometric recruitment curves with time are also demonstrated.<>
Keywords
bioelectric phenomena; muscle; anesthetized cats; electrically stimulated muscle; isometric recruitment curves; ramp deconvolution method; resolution curve; step response method;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1988. Proceedings of the Annual International Conference of the IEEE
Conference_Location
New Orleans, LA, USA
Print_ISBN
0-7803-0785-2
Type
conf
DOI
10.1109/IEMBS.1988.94845
Filename
94845
Link To Document