DocumentCode
3459928
Title
Experimental results and design guidelines derived from the testing of a 2 MW, 250 Hz, auxiliary resonant commutated pole bi-directional converter
Author
Herbst, J.D. ; Thelen, R.F. ; Gattozzi, A.L. ; Williams, A.S.
Author_Institution
Center for Electromech., Univ. of Texas, Austin, TX
fYear
2008
fDate
24-28 Feb. 2008
Firstpage
1240
Lastpage
1246
Abstract
An auxiliary resonant commutated pole (ARCP) converter, rated for an output of 2 MW at 250 Hz, has been built and has undergone preliminary tests at the University of Texas at Austin Center for Electromechanics (UT-CEM). Experimental results are reported on its testing as the bi-directional link between a power DC bus and a flywheel energy storage system. Design issues encountered in the course of development of the converter and the system are discussed and some considerations are made regarding the application of soft-switching ARCP-type converters versus their hard-switched counterpart.
Keywords
commutation; flywheels; resonant power convertors; switching convertors; University of Texas at Austin Center for Electromechanics; auxiliary resonant commutated pole bidirectional converter; flywheel energy storage system; frequency 250 Hz; power 2 MW; power DC bus; soft-switching application; Bidirectional control; Flywheels; Guidelines; Induction generators; Induction machines; Induction motors; Power generation; Resonance; Testing; Traction motors; ARCP converters; Resonant power converters; soft-switching converters;
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference and Exposition, 2008. APEC 2008. Twenty-Third Annual IEEE
Conference_Location
Austin, TX
ISSN
1048-2334
Print_ISBN
978-1-4244-1873-2
Electronic_ISBN
1048-2334
Type
conf
DOI
10.1109/APEC.2008.4522881
Filename
4522881
Link To Document