• DocumentCode
    3461227
  • Title

    Evaluation of the energy-saving performance of the PMSM drive system

  • Author

    Kawai, H. ; Tasaka, Y.

  • Author_Institution
    Toshiba Corp., Tokyo, Japan
  • fYear
    2010
  • fDate
    21-24 June 2010
  • Firstpage
    1605
  • Lastpage
    1608
  • Abstract
    This paper mentions about the permanent-magnet synchronous motor (PMSM) propulsion system and its energy-saving performance confirmed through running tests on the Ginza Line of Tokyo Metro Co., Ltd. Comparing the conventional IM system installed Ginza Line with the PMSM system, the PMSM propulsion system has achieved 12.5% power consumption reduction in powering. In this paper, we describe the outline of the PMSM propulsion system and show results of the energy-saving performance evaluation tests carried out for more than 1.5 years.
  • Keywords
    electric propulsion; energy conservation; permanent magnet motors; power consumption; synchronous motor drives; Ginza Line of Tokyo Metro Company; PMSM drive system; PMSM propulsion system; energy-saving performance; performance evaluation tests; permanent-magnet synchronous motor; power consumption reduction; propulsion system; Circuit testing; Electronic equipment testing; Energy consumption; Inverters; Power electronics; Propulsion; Rail transportation; Synchronous motors; System testing; Voltage; Energy-saving; PMSM; VVVF;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Conference (IPEC), 2010 International
  • Conference_Location
    Sapporo
  • Print_ISBN
    978-1-4244-5394-8
  • Type

    conf

  • DOI
    10.1109/IPEC.2010.5543365
  • Filename
    5543365