• DocumentCode
    3461607
  • Title

    Material strength examination of thin film PDMS for reliable pneumatic balloon actuator

  • Author

    Matsushita, Yuki ; Nakagami, C. ; Toriyama, T. ; Konishi, Satoshi

  • Author_Institution
    Ritsumeikan Univ., Kusatsu, Japan
  • fYear
    2013
  • fDate
    16-20 June 2013
  • Firstpage
    1950
  • Lastpage
    1953
  • Abstract
    This paper examines the material strength of thin film PDMS widely used for biomedical MEMS and μTAS. This study focuses on the material strength of PBA membrane. Stress-strain diagram of PDMS is examined through the tensile test. Breaking strength is also estimated with an aim to relate with the fracture of balloon membrane of PBA. As the result of PDMS tensile test, non-linear stress-strain relation could be observed. We defined stress as T and l´/l as λ(here, l is distance between two diamond-shaped gauge marks, l´ is l+Δl). Logarithmic relationship between T and λ plays important role for analysis of mechanical behavior of polymer such as PDMS by the neo-Hookean constitutive equation.
  • Keywords
    actuators; bioMEMS; microactuators; μTAS; biomedical MEMS; material strength examination; neo-Hookean constitutive equation; reliable pneumatic balloon actuator; stress-strain diagram; thin film PDMS; Actuators; Films; Finite element analysis; Minimally invasive surgery; Reliability; Stress; Material strength examination; PDMS; Pneumatic balloon actuator;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII), 2013 Transducers & Eurosensors XXVII: The 17th International Conference on
  • Conference_Location
    Barcelona
  • Type

    conf

  • DOI
    10.1109/Transducers.2013.6627176
  • Filename
    6627176