DocumentCode
3461967
Title
Estimation of ischemic tolerance time of rat liver by ultrasonic spectroscopy investigations
Author
Jenderka, Klaus-Vitold ; Gartner, Thomas ; Steinke, Thomas ; Knaut, Michael ; Cobet, Ulrich
Author_Institution
Inst. of Med. Phys. & Biophys., Martin-Luther-Univ., Halle-Wittenberg, Germany
Volume
2
fYear
1996
fDate
3-6 Nov 1996
Firstpage
1599
Abstract
As a result of isolation from blood circulation in any organ the ischemic stress causes alterations in the physiological state of the cells. After the ischemic tolerance time the tissue is in a condition where resuscitation is no longer possible. Therefore the monitoring of the present state of the organ is a requirement in the investigations on the probability of successful revival of the organ. The modifications in the physiological state and in the tissue structure due to ischemic stress also alters the elasto-acoustic properties of the tissue. These effects can be detected by ultrasonic spectroscopy. The process of ischemia in rat liver specimen was investigated by the spectral analysis of the backscattered RF-data. The condition of the organ tissue was described by means of two frequency dependent acoustical parameters, the attenuation and the backscatter parameter, respectively. To improve the reliability of the method a set of independent scanlines of the specimen was used (B-mode like image). A dependence of the acoustic parameters on time, type of protection solution and temperature during ischemia was found. The use of a set of scanlines provides more information about the quality of the perfusion and protects from the inclusion of disruptive elements in the parameter analysis
Keywords
backscatter; bioacoustics; biological techniques; liver; B-mode like image; acoustic parameters; backscattered RF-data; blood circulation; cellular physiological state alterations; ischemic stress; ischemic tolerance time estimation; organ state monitoring; parameter analysis; perfusion quality; rat liver; resuscitation; scanlines set; successful organ revival; tissue elastoacoustic properties; ultrasonic spectroscopy investigations; Acoustic signal detection; Biomedical monitoring; Cells (biology); Frequency dependence; Ischemic pain; Liver; Protection; Spectral analysis; Spectroscopy; Stress;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 1996. Proceedings., 1996 IEEE
Conference_Location
San Antonio, TX
ISSN
1051-0117
Print_ISBN
0-7803-3615-1
Type
conf
DOI
10.1109/ULTSYM.1996.584394
Filename
584394
Link To Document