DocumentCode
3464365
Title
Comparison of ferromagnetic resonance and damping in permalloy films using time and frequency domain techniques
Author
Pasquale, M. ; Bertotti, G. ; Olivetti, E. ; Coisson, M. ; Celegato, F. ; Kuepferling, M. ; Endo, Y. ; Mitsuzuka, Y. ; Yamaguchi, M. ; Serrano-Guisan, S. ; Schumacher, H.W. ; Kabos, P.
Author_Institution
INRiM, Torino, Italy
fYear
2010
fDate
13-18 June 2010
Firstpage
333
Lastpage
334
Abstract
This paper describes the results of a comparison between measurements of FMR frequency and the Gilbert damping constant α made using time and frequency domain experimental techniques. The measurements were performed on reference samples circulated among different laboratories within the frame of an ongoing European and transnational research projects.
Keywords
Permalloy; ferromagnetic resonance; frequency measurement; frequency-domain analysis; time-domain analysis; European research projects; FMR frequency measurements; Gilbert damping constant; ferromagnetic resonance; frequency domain experimental techniques; permalloy films; reference samples; time domain experimental techniques; transnational research projects; Damping; Extraterrestrial measurements; Frequency domain analysis; Frequency measurement; Magnetic anisotropy; Magnetic field measurement; Magnetic resonance; Saturation magnetization; Soft magnetic materials; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location
Daejeon
Print_ISBN
978-1-4244-6795-2
Type
conf
DOI
10.1109/CPEM.2010.5543561
Filename
5543561
Link To Document