Title :
Method for eliminating magnetic saturation due to fast transient response in DC-DC converter
Author :
Kohama, Teruhiko ; Inoue, Akio
Abstract :
Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. The magnetic saturation is observed in onboard isolated bridge-type DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Based on the analysis a solution for the magnetic saturation is proposed. The effectiveness of proposed method is also confirmed by experiments.
Keywords :
DC-DC power convertors; PWM power convertors; transient response; DC-DC converter; asymmetrical PWM signal; fast dynamic response; fast transient response; magnetic saturation; Capacitors; Circuit faults; DC-DC power converters; Magnetic circuits; Magnetic cores; Pulse width modulation; Saturation magnetization; Transformer cores; Transient response; Video recording; bridge-type converter; fast transient response; magnetic saturation;
Conference_Titel :
Power Electronics Conference (IPEC), 2010 International
Conference_Location :
Sapporo
Print_ISBN :
978-1-4244-5394-8
DOI :
10.1109/IPEC.2010.5543584