DocumentCode :
3465191
Title :
Micro-Magnetocardiography System with a Single-Chip SQUID Magnetometer Array for QT Analysis and Diagnosis of Myocardial Injury in Small Animals
Author :
Komamura, K. ; Kawai, J. ; Miyamoto, M. ; Adachi, Y. ; Uehara, G. ; Haruta, Y.
Author_Institution :
Res. Inst., Suita
fYear :
2007
fDate :
19-22 Aug. 2007
Firstpage :
33
Lastpage :
35
Abstract :
Development of drugs needs electrophysiological studies of small animals like mice, rats or guinea pigs. Electrocardiography (ECG) of hirsute animals is time-consuming. We have developed a micro magnetometer array with 9-channel superconducting quantum interference device (SQUID) with 2.5-mm diameter pickup-coil for non-contact measurement of magnetocardiogram (MCG) in small animals. The micro-MCG successfully recorded PQRST complex in mice, rats and guinea pigs. Regional myocardial injury was made with cryoinjury probe in rat hearts, and the injured pattern in MCG was recorded. Anterior myocardial injury created QS pattern in MCG, and posterior myocardial injury created QR pattern in MCG. Quinidine-induced QT prolongation was successfully detected by micro MCG in mice and rats. Simultaneous recording of ECG and MCG after intraperitoneal administration of quinidine (60 mg/kg) in guinea pigs. Both QTc in ECG and MCG correlated well. Newly developed micro MCG may facilitate the research process of electrophysiological studies of small animals, and may enable high throughput screening of drug-induced QT abnormality.
Keywords :
SQUID magnetometers; bioMEMS; bioelectric phenomena; drugs; magnetocardiography; ECG; PQRST complex; cryoinjury probe; drug-induced QT abnormality; electrocardiography; electrophysiological study; guinea pig; intraperitoneal administration; microMCG; micromagnetocardiography system; myocardial injury diagnosis; noncontact measurement; pickup-coil; quinidine-induced QT prolongation; rat heart; single-chip SQUID magnetometer array; size 2.5 mm; small animal; superconducting quantum interference device; Animals; Drugs; Electrocardiography; Injuries; Magnetic analysis; Mice; Myocardium; Rats; SQUID magnetometers; Superconducting devices;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Medical Devices and Biosensors, 2007. ISSS-MDBS 2007. 4th IEEE/EMBS International Summer School and Symposium on
Conference_Location :
Cambridge
Print_ISBN :
978-1-4244-1346-1
Electronic_ISBN :
978-1-4244-1346-1
Type :
conf
DOI :
10.1109/ISSMDBS.2007.4338286
Filename :
4338286
Link To Document :
بازگشت