• DocumentCode
    3465642
  • Title

    Comparison of different methods of inductance realisation

  • Author

    Eklund, G. ; Satrapinski, A. ; Suomalainen, E-P ; Semenov, Yu

  • Author_Institution
    SP Tech. Res. Inst. of Sweden, Borås, Sweden
  • fYear
    2010
  • fDate
    13-18 June 2010
  • Firstpage
    382
  • Lastpage
    383
  • Abstract
    A comparison of inductance realisation at 100 mH was carried out in October -November 2009 at MIKES and SP. The measurand was a four terminal pair toroidal inductor measured at three frequencies 400 Hz, 1000 Hz and 1591 Hz. Realisations by series and parallel resonance methods and by a 2 DVM sampling method were used. The results showed agreement within combined expanded uncertainty.
  • Keywords
    inductance measurement; resonance; sampling methods; frequency 1000 Hz; frequency 1591 Hz; frequency 400 Hz; inductance realisation; parallel resonance method; sampling method; toroidal inductor; Bridge circuits; Capacitance; Electrical resistance measurement; Frequency measurement; Impedance; Inductance measurement; Inductors; Resonance; Sampling methods; Voltage;