DocumentCode
3465642
Title
Comparison of different methods of inductance realisation
Author
Eklund, G. ; Satrapinski, A. ; Suomalainen, E-P ; Semenov, Yu
Author_Institution
SP Tech. Res. Inst. of Sweden, Borås, Sweden
fYear
2010
fDate
13-18 June 2010
Firstpage
382
Lastpage
383
Abstract
A comparison of inductance realisation at 100 mH was carried out in October -November 2009 at MIKES and SP. The measurand was a four terminal pair toroidal inductor measured at three frequencies 400 Hz, 1000 Hz and 1591 Hz. Realisations by series and parallel resonance methods and by a 2 DVM sampling method were used. The results showed agreement within combined expanded uncertainty.
Keywords
inductance measurement; resonance; sampling methods; frequency 1000 Hz; frequency 1591 Hz; frequency 400 Hz; inductance realisation; parallel resonance method; sampling method; toroidal inductor; Bridge circuits; Capacitance; Electrical resistance measurement; Frequency measurement; Impedance; Inductance measurement; Inductors; Resonance; Sampling methods; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location
Daejeon
Print_ISBN
978-1-4244-6795-2
Type
conf
DOI
10.1109/CPEM.2010.5543638
Filename
5543638
Link To Document