    Development of high collection efficiency ESP by barrier discharge system

  • Author

    Kawada, Yoshihiro ; Kubo, Takafumi ; Ehara, Yoshiyasu ; Ito, Tairo ; Zukeran, Akinori ; Takahashi, Takeo ; Kawakami, Hitomi ; Takamatsu, Takeshi

  • Author_Institution
    Musashi Inst. of Technol., Tokyo, Japan
  • Volume
    2
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    1130
  • Abstract
    One of the electrostatic precipitator (ESP) applications is the cleaning in superhighway tunnels. In superhighway tunnels, contaminants in the air are carbon particles, NOx etc. The ESP consists of the precharger and collecting section. The ESP can little remove NOx, when corona discharge is used as a precharger. The autors suggest a barrier discharge-type precharger instead of corona discharge. In this work, experiments were carried out using small two-stage type ESP with barrier discharge. As a result, it was shown that the particle collection efficiency and NOx removal rate were high in barrier discharge type ESP
  • Keywords
    air pollution control; discharges (electric); electrostatic precipitators; NO; NOx removal rate; barrier discharge system; barrier discharge-type precharger; electrostatic precipitator; high-collection efficiency ESP; particle collection efficiency; superhighway tunnel cleaning; Carbon dioxide; Cleaning; Corona; Density measurement; Electrodes; Electrostatic precipitators; Fault location; Particle measurements; Sampling methods; Voltage;
  • fLanguage