    PMU performance requirements and validation for closed loop applications

  • Author

    Lira, R. ; Mycock, C. ; Wilson, D. ; Kang, H.

  • Author_Institution
    Psymetix. Edinburgh, Edinburgh, UK
  • fYear
    2011
  • fDate
    5-7 Dec. 2011
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    Wide Area Measurement Systems (WAMS) are increasingly used to observe the static and dynamic performance of power systems. Synchronised phasor measurements are also a valuable wide-area input to control and protection schemes. It is important that PMUs perform correctly for the various purposes that the data is used for. Standard and type testing is valuable, but it is also necessary to have the capability to perform specific tests for the monitoring and control applications. In particular, where phasor measurements are applied to control schemes, it is important to assess the requirements and impact of the PMU data quality on the control scheme. This paper details the findings of the authors in the field of practical design and implementation of PMU´s (Phasor measurement Units) in a system. The required response of PMU´s under various types of system disturbances is examined through simulation of disturbances in a large power system. The response of the PMU required for power system stability applications is examined and tested for frequency variations and presence of harmonics in the system. The paper presents the simulation setup and the thought process behind creating a virtual setup for developing and testing PMU applications. This simulation environment allows testing of the system response with closed loop control involving phasor measurements. This approach can be used to prove the control scheme, and also to develop the requirements for the PMU speed, accuracy and communications latency for correct operation of the schemes under test.
  • Keywords
    closed loop systems; phasor measurement; power system control; power system stability; PMU performance requirements; closed loop applications; closed loop control; large power system; synchronised phasor measurements; wide area measurement systems; Accuracy; Delay; Monitoring; Oscillators; Phasor measurement units; Steady-state; Transmission line measurements; Phasor Measurement Unit (PMU); Real Time; Stability; Wide Area Measurements keywords;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Innovative Smart Grid Technologies (ISGT Europe), 2011 2nd IEEE PES International Conference and Exhibition on
  • Conference_Location
    Manchester
  • ISSN
    2165-4816
  • Print_ISBN
    978-1-4577-1422-1
  • Electronic_ISBN
    2165-4816
  • Type

    conf

  • DOI
    10.1109/ISGTEurope.2011.6162636
  • Filename
    6162636