DocumentCode
3467325
Title
High-voltage pulse generator based on magnetic pulse compression and transmission line transformer
Author
Jiajin Lin ; Jiande Zhang ; Jianhua Yang
Author_Institution
Coll. of Optoelectric Sci. & Eng., Nat. Univ. of Defense Technol., Changsha, China
fYear
2013
fDate
16-21 June 2013
Firstpage
1
Lastpage
4
Abstract
An all-solid-state high-voltage pulse generator based on magnetic pulse compression (MPC) and transmission line transformer (TLT) is presented. A closed magnetic core transformer switched with thyristors is used as a fast step up charging source for the primary capacitor of MPC. Three high voltage coaxial 50 Ω cables are connected as a three stages TLT with the input impedance of 17 Ω and the output impedance of 150 Ω. By means of combination of MPC and TLT, this pulse generator can deliver a high-voltage pulse with a duration of 68 ns, amplitude of 90 kV, and rise time of 20 ns on the 150 Ω matched load.
Keywords
coaxial cables; magnetic cores; power transformers; pulse generators; thyristors; MPC; all-solid-state high-voltage pulse generator; closed magnetic core transformer; fast step up charging source; high voltage coaxial cables; high-voltage pulse; magnetic pulse compression; primary capacitor; three stages TLT; thyristors; time 20 ns; time 68 ns; transmission line transformer; Impedance; Magnetic cores; Magnetic materials; Photonic crystals; Power transmission lines; Pulse transformers; Windings;
fLanguage
English
Publisher
ieee
Conference_Titel
Pulsed Power Conference (PPC), 2013 19th IEEE
Conference_Location
San Francisco, CA
ISSN
2158-4915
Type
conf
DOI
10.1109/PPC.2013.6627506
Filename
6627506
Link To Document