• DocumentCode
    3468395
  • Title

    Sensitivity of inductances to magnetic fields

  • Author

    Brendel, R. ; Claudel, G. ; Baviere, P.

  • Author_Institution
    Lab. de Phys. et Metrol. des Oscillateurs, CNRS, Besancon, France
  • fYear
    1996
  • fDate
    5-7 Mar 1996
  • Firstpage
    170
  • Lastpage
    175
  • Abstract
    This paper presents a method used to measure the magnetic sensitivity of inductances. The measurement is performed by using an LC oscillator whose frequency is determined by the inductance to be measured. Because the records are often perturbed by noises and drift the data are processed so as to enhance the signal-to-noise ratio and to suppress the drift. A wide range of inductances have been measured. The results show that, according to their technology, for a magnetic field of 10 Gauss amplitude, the sensitivity may go from 0.1 ppm to 1400 ppm with sometimes a large spread of values in a given batch
  • Keywords
    frequency measurement; LC oscillator; drift suppression; inductances; magnetic fields; magnetic sensitivity; signal-to-noise ratio;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    European Frequency and Time Forum, 1996. EFTF 96., Tenth (IEE Conf. Publ. 418)
  • Conference_Location
    Brighton
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-661-X
  • Type

    conf

  • DOI
    10.1049/cp:19960040
  • Filename
    584853