DocumentCode
3470127
Title
A novel full 2-port calibration method for antenna measurements using sol standards without through procedure
Author
Hirose, Masanobu ; Komiyama, Koji
Author_Institution
Nat. Inst. of Adv. Ind. Sci. & Technol., Nat. Metrol. Inst. of Japan, Tsukuba, Japan
fYear
2010
fDate
13-18 June 2010
Firstpage
329
Lastpage
330
Abstract
We have proposed a novel method to calibrate a vector network analyzer (VNA) using only Short-Open-Load (SOL) standards without Thru (T) procedure in a full 2-port calibration, which is especially suitable for reciprocal antenna measurements because of the easiness of its procedure, and have shown that the systematic uncertainty is almost the same as that of the SOLT calibration method. In this paper, we show that there is the similar condition on the signal to noise ratio (SNR) for the calibration methods. Therefore, it is proved that the method is simpler than the SOLT calibration method with equivalent effectiveness.
Keywords
antennas; calibration; network analysers; SNR; SOL standards; SOLT calibration method; antenna measurements; full 2-port calibration method; short-open-load standards; signal-to-noise ratio; vector network analyzer; Antenna measurements; Cables; Calibration; Electromagnetic analysis; Electromagnetic measurements; Flow graphs; Measurement standards; Metrology; Scattering parameters; Signal to noise ratio;
fLanguage
English