• DocumentCode
    3471057
  • Title

    The practical use of a computerised partial discharge measuring system for online condition monitoring of high voltage stator windings

  • Author

    Watt, G. ; Kouadria, D.

  • Author_Institution
    Eleco Dowding & Mills, Aberdeen, UK
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    112
  • Lastpage
    117
  • Abstract
    This paper describes the design and development of a computer aided online technique to enable the detection and identification of HV electric machine stator winding insulation problems by nonspecialized operators. This can help in the prevention of failure and enables the manufacturer and user to assess ageing and controlled outage of equipment. Typical examples of its application on machine insulating systems partial discharge measurements are also presented
  • Keywords
    electric machines; HV electric machine; ageing; computerised partial discharge measuring system; controlled outages; high voltage stator windings; insulation breakdown testing; online condition monitoring; partial discharge measurements;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1999. Ninth International Conference on (Conf. Publ. No. 468)
  • Conference_Location
    Canterbury
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-720-9
  • Type

    conf

  • DOI
    10.1049/cp:19991000
  • Filename
    816366