DocumentCode :
347135
Title :
Stress and strain in the human distal phalanx under indentation
Author :
Bowden, Anton E. ; Rabbitt, Richard D. ; Weiss, Jeffrey A.
Author_Institution :
Dept. of Bioeng., Univ. of Utah, Salt Lake City, UT, USA
Volume :
1
fYear :
1999
fDate :
1999
Abstract :
An image-based technique was used to track stress and strain fields in the human finger under compressional loading. Magnetic Resonance (MR) images were taken before and during compressional loading of the finger tissue. These images were used to drive nonlinear deformation of a finite element (FE) model of the tissue
Keywords :
biological tissues; biomechanics; biomedical MRI; finite element analysis; image registration; kinematics; medical image processing; MRI; compressional loading; finger biomechanics; human distal phalanx; human finger; image-based technique; indentation; magnetic resonance images; strain fields tracking; stress fields tracking; Biomedical engineering; Capacitive sensors; Deformable models; Fingers; Finite element methods; Humans; Image coding; Magnetic field induced strain; Stress; Target tracking;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
[Engineering in Medicine and Biology, 1999. 21st Annual Conference and the 1999 Annual Fall Meetring of the Biomedical Engineering Society] BMES/EMBS Conference, 1999. Proceedings of the First Joint
Conference_Location :
Atlanta, GA