• DocumentCode
    3471837
  • Title

    Modeling strategy for background compensation in repeat cerebral blood flow quantitation with diffusible tracers

  • Author

    Iida, H. ; Watabe, H. ; Shidahara, M. ; Kim, K. Min ; Takikawa, S. ; Ogura, T. ; Hayashida, K. ; Ishida, Y.

  • Author_Institution
    Dept. of Investigative Radiol., Nat. Cardiovascular Centre Res. Inst., Osaka, Japan
  • Volume
    3
  • fYear
    2000
  • fDate
    2000
  • Abstract
    A method has been developed for repeat quantitation of regional cerebral blood flow (rCBF) using a diffusible tracer such as O-15 water (H215O) and I-123 iodo-amphetamine (123IMP). The background activity distribution due to the previous tracer administration was formulated according to a compartment model, so as to allow initiation of the next scan while residual radioactivity exists, minimizing the intervals between scans. This background distribution was estimated from the previous scan with the minimum enhancement of the statistical noise. Theoretical simulation study was carried out, and demonstrated that the estimated images of the transient tracer distribution are highly weighted on transient rCBF immediately after the tracer administration, and that the change of rCBF after a certain period has only small contribution to the estimated tracer distributions. Another set of simulation study showed that estimated rCBF was sensitive to the transient rCBF only immediately after the tracer administration, and that the change after a certain period does not contribute to the rCBF estimated by the present approach. This technique was then applied to a clinical test-retest study using IMP and SPECT. Reproducibility of rCBF quantified by this approach was less than 5% in 5 studies performed at rest-rest condition, and vascular reactivity determined by a rest-vasodilating drug stimulation (Rest-Diamox) on 5 healthy volunteers appeared to be 40%, which was in an agreement with literature value. We thus conclude that repeat rCBF quantitation is feasible with considerably shorter intervals than the present protocol, and can be applied to clinical studies
  • Keywords
    biodiffusion; brain; haemodynamics; medical image processing; positron emission tomography; radioactive tracers; single photon emission computed tomography; I-123 iodoamphetamine; O-15 water; PET; SPECT; background activity distribution; background compensation; compartment model; diffusible tracer; modeling strategy; regional cerebral blood flow; repeat quantitation; rest-rest condition; rest-vasodilating drug stimulation; transient tracer distribution; vascular reactivity; Background noise; Blood flow; Cardiology; Cities and towns; Hospitals; Mathematical model; Neurosurgery; Radiology; Reproducibility of results; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2000 IEEE
  • Conference_Location
    Lyon
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-6503-8
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2000.949224
  • Filename
    949224