DocumentCode
3471919
Title
Effect of power factor on rotor loss in high-speed PM alternators
Author
Sharkh, S.A. ; Irenji, Neamat Taghizadeh ; Harris, Martyn
Author_Institution
Southampton Univ., UK
fYear
1999
fDate
1999
Firstpage
346
Lastpage
350
Abstract
Rotor electromagnetic loss in high-speed PM machines can be significant, causing overheating leading to failure. The paper calculates rotor loss in a 50 kW high speed alternator for different load power factors. A multi-layer current sheet model that was published previously by the authors is used to calculate the loss for each airgap flux harmonic travelling wave. The harmonics are evaluated from a number of magnetostatic FE solutions of the machine at different rotor positions. A close examination of the loss caused by each harmonic shows that MMF slot harmonics combine with no-load harmonics so as to increase rotor loss as the power factor changes from inductive to capacitive. The paper also discusses the accuracy of the current sheet model and presents results on the interaction between rotor eddy current flux and stator teeth which is not accounted for in the current sheet model. The results show that for the alternator under study this effect introduces less than 6% error in the calculation of rotor loss
Keywords
permanent magnet generators; 50 kW; MMF slot harmonics; airgap flux harmonic travelling wave; capacitive power factor; current sheet model accuracy; high-speed PM alternators; load power factors; loss; magnetostatic FE solutions; multi-layer current sheet model; no-load harmonics; overheating; power factor effect; rotor electromagnetic loss; rotor loss; rotor positions;
fLanguage
English
Publisher
iet
Conference_Titel
Electrical Machines and Drives, 1999. Ninth International Conference on (Conf. Publ. No. 468)
Conference_Location
Canterbury
ISSN
0537-9989
Print_ISBN
0-85296-720-9
Type
conf
DOI
10.1049/cp:19991048
Filename
816414
Link To Document