    Quantitative cardiac PET imaging: reproducibility in an integrated analysis environment

  • Author

    Nekolla, S.G. ; Balbach, T. ; Neverve, J. ; Bengel, F.G. ; Schwaiger, M.

  • Author_Institution
    Nuklearmed. Klinik, Tech. Univ. Munchen, Germany
  • Volume
    3
  • fYear
    2000
  • fDate
    2000
  • Abstract
    The strength of PET imaging in nuclear cardiology relies significantly on the usage of physiological contrast agents such as water or glucose analogues in very small doses in order to assess function, perfusion and metabolism. However, one is continually challenged with maintaining a balance between acquisition capabilities, physiological knowledge and applications in patient care. The more recent use of dynamic studies with high temporal resolution or as function of the heart phases has extended the spectrum of functional, non-invasive cardiac imaging. However, this is paralleled with a drastic increase in data and lack of sufficient means of data analysis. In order to cope with these demands of extracting physiological information from vast amounts of physical data, the analysis environment `MunichHeart´ was developed. Three quantitative analysis modules from this tool box are investigated with respect to intra- and interobserver variability: the assessment of myocardial viability, the delineation of absolute myocardial blood flow and the measurement of left ventricular ejection fraction. The results demonstrate that reproducibility, stability and flexibility can be achieved both in a research oriented environment as well as for routine applications. This is the necessary prerequisite to facilitate the transfer of new methods into clinical reality
  • Keywords
    cardiology; image resolution; positron emission tomography; PET reproducibility; integrated analysis environment; interobserver variability; intraobserver variability; medical diagnostic imaging; myocardial viability assessment; nuclear medicine; quantitative cardiac PET imaging; Biochemistry; Cardiology; Data analysis; Heart; High-resolution imaging; Image resolution; Myocardium; Positron emission tomography; Reproducibility of results; Sugar;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2000 IEEE
  • Conference_Location
    Lyon
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-6503-8
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2000.949237
  • Filename
    949237