DocumentCode
3472389
Title
Bridging RF-voltage to coaxial power standard in the 100 MHz range
Author
Brunetti, L. ; Bussa, M.P. ; Oberto, L. ; Sellone, M.
Author_Institution
Ist. Naz. di Ricerca Metrol. (INRIM), Torino, Italy
fYear
2010
fDate
13-18 June 2010
Firstpage
740
Lastpage
741
Abstract
Electromagnetic power standard realized by means of the microcalorimetric technique fails below some MHz because of a reduced sensitivity of the system. This causes a metrological lack in the calibration of coaxial power sensors whose broadband characteristics span from dc up to 50 GHz. However, as coaxial transmission lines admit pseudo potential functions, power meter calibration can be done in term of radio frequency (RF) voltage from dc up to 100 MHz at least. The paper describes how INRIM works around the drawback of the microcalorimeter at low frequencies.
Keywords
calorimeters; coaxial cables; electric sensing devices; power meters; transmission lines; bridging RF-voltage; broadband characteristics span; coaxial power sensors; coaxial transmission lines; electromagnetic power standard; frequency 100 MHz; microcalorimetric technique; power meter calibration; pseudopotential functions; radiofrequency voltage; Analog-digital conversion; Coaxial components; Detectors; Frequency measurement; Measurement standards; Radio frequency; Sensor phenomena and characterization; Sensor systems; Thermoelectricity; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location
Daejeon
Print_ISBN
978-1-4244-6795-2
Type
conf
DOI
10.1109/CPEM.2010.5544022
Filename
5544022