DocumentCode
3472912
Title
The effect of neglecting autocorrelation on the performance of T2 control charts in monitoring of logistic profiles
Author
Amiri, Ali ; Koosha, Mohammad
Author_Institution
Dept. of Ind. Eng., Shahed Univ., Tehran, Iran
fYear
2011
fDate
14-17 Sept. 2011
Firstpage
264
Lastpage
267
Abstract
There are many researches in the area of profile monitoring and most of them have two basic assumptions including the normality of response variable as well as independency of observations within each profile. In recent years there are some researches investigating the violation of the assumptions. This paper shows the effect of ignoring autocorrelation on the performance of T2 control chart when the response variable follows a binomial distribution. Besides, a simple method is proposed to account for this effect in the T2 control chart. At the end, the performance of the proposed method is evaluated using simulation studies.
Keywords
binomial distribution; control charts; logistics; process monitoring; T2 control charts; autocorrelation; binomial distribution; logistic profile monitoring; Computational modeling; Control charts; Correlation; Logistics; Maximum likelihood estimation; Monitoring; Process control; Autocorrelation; Logistic regression; Profile monitoring; T2 control chart;
fLanguage
English
Publisher
ieee
Conference_Titel
Quality and Reliability (ICQR), 2011 IEEE International Conference on
Conference_Location
Bangkok
Print_ISBN
978-1-4577-0626-4
Type
conf
DOI
10.1109/ICQR.2011.6031722
Filename
6031722
Link To Document