• DocumentCode
    3473418
  • Title

    Realistic Monte Carlo simulation of Ga-67 imaging for optimization and evaluation of correction methods

  • Author

    Moore, S.C. ; El Fakhri, G.

  • Author_Institution
    Dept. of Radiol., Brigham & Women´´s Hosp., Boston, MA, USA
  • Volume
    3
  • fYear
    2000
  • fDate
    2000
  • Abstract
    Describes a comprehensive Monte Carlo program tailored for efficient simulation of realistic Ga-67 SPECT data through the entire range of photon emission energies. The program incorporates several new features developed by us and by others, and is now being used to optimize and evaluate the performance of various methods of compensating for photon scatter, attenuation, and nonstationary distance- and energy-dependent detector resolution. Improvements include (a) the use of a numerical torso phantom with accurate organ source and attenuation maps obtained by segmenting CT images of an RSDTM anthropomorphic heart/thorax phantom, modified to include 8 axillary lymph nodes, (b) accelerated photon propagation through the attenuator using a variant of the maximum rectangular region (MRR) algorithm of Suganuma and Ogawa, and (c) improved variance reduction using modified spatial sampling for simulation of large-angle collimator penetration, scatter and lead X-rays. Very-high-count projections were simulated in 55 energy windows spaced irregularly in the range, 60-370 keV; these essentially noise-free images are used as a basis for generating Poisson noise realizations characteristic of 72-hour post-injection Ga-67 studies. Comparisons of spatial and energy distributions demonstrate good agreement between data experimentally measured from the RSD phantom and those simulated from the mathematical segmentation of the same phantom
  • Keywords
    Monte Carlo methods; gamma-ray absorption; medical image processing; optimisation; single photon emission computed tomography; 60 to 370 keV; 72 h; Ga; Ga-67 imaging; accurate organ source; anthropomorphic heart/thorax phantom; axillary lymph nodes; correction methods optimization; energy-dependent detector resolution; large-angle collimator penetration; medical diagnostic imaging; modified spatial sampling; nuclear medicine; numerical torso phantom; realistic Monte Carlo simulation; variance reduction; Attenuation; Electromagnetic scattering; Image segmentation; Imaging phantoms; Monte Carlo methods; Noise generators; Optimization methods; Particle scattering; Single photon emission computed tomography; X-ray scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2000 IEEE
  • Conference_Location
    Lyon
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-6503-8
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2000.949312
  • Filename
    949312