Title :
An automatic method for the estimation of Arteriolar-to-Venular Ratio in retinal images
Author :
Dashtbozorg, Behdad ; Mendonca, Ana Maria ; Campilho, Aurelio
Author_Institution :
INEB-Inst. de Eng. Biomed., Porto, Portugal
Abstract :
This paper presents an automatic approach for the estimation of Arteriolar-to-Venular Ratio (AVR) in retinal images. The method was assessed using the images of the INSPIRE-AVR database. A mean error of 0.05 was obtained when the method´s results were compared with reference AVR values provided with this dataset, thus demonstrating the adequacy of the proposed solution for AVR estimation.
Keywords :
blood vessels; eye; image classification; image segmentation; medical image processing; vision; AVR estimation; INSPIRE-AVR database; arteriolar-venular ratio estimation; automatic method; mean error; reference AVR values; retinal images; Adaptive optics; Arteries; Image segmentation; Observers; Optical imaging; Retina; Veins;
Conference_Titel :
Computer-Based Medical Systems (CBMS), 2013 IEEE 26th International Symposium on
Conference_Location :
Porto
DOI :
10.1109/CBMS.2013.6627854