DocumentCode :
3478377
Title :
Characterization for graphene as heat spreader using thermal imaging method
Author :
Shirong Huang ; Yong Zhang ; Shuangxi Sun ; Xiaogang Fan ; Ling Wang ; Yifeng Fu ; Yan Zhang ; Johan Liu
Author_Institution :
Dept. of Electron. Inf. Mater., Shanghai Univ., Shanghai, China
fYear :
2013
fDate :
11-14 Aug. 2013
Firstpage :
403
Lastpage :
408
Abstract :
Monolayer graphene was synthesized through thermal chemical vapor deposition (TCVD) as heat spreader in electronic packaging. Platinum (Pt) was functioned as hot spot of thermal testing chip. The hot spot temperature of thermal testing chip bonded onto a heat sink measured by an FLIR infrared thermograph was decreased by about 5 °C from 52 °C to 47 °C when driven at a heat flux about 1280W/cm2 with a graphene heat spreader attached. It is conceivable that further improvements to the cooling performance of graphene heat spreader can be made by optimizing the synthesis parameters and transfer process.
Keywords :
chemical vapour deposition; cooling; electronics packaging; graphene; heat sinks; infrared imaging; platinum; FLIR infrared thermograph; Pt; TCVD; cooling performance; electronic packaging; heat flux; heat sink; heat spreader; hot spot temperature; monolayer graphene; synthesis parameter optimization; temperature 52 degC to 47 degC; thermal chemical vapor deposition; thermal imaging method; thermal testing chip; transfer process; Graphene; Heat sinks; Resistance heating; Temperature measurement; Testing; Thermal resistance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronic Packaging Technology (ICEPT), 2013 14th International Conference on
Conference_Location :
Dalian
Type :
conf
DOI :
10.1109/ICEPT.2013.6756500
Filename :
6756500