DocumentCode
3480870
Title
Active control of the pressure pulsation in large-flow mixed gas pipe
Author
Xie, Yudong ; Liu, Yanjun ; Wang, Yong
Author_Institution
Sch. of Mech. Eng., Shandong Univ., Jinan, China
fYear
2009
fDate
5-7 Aug. 2009
Firstpage
1639
Lastpage
1642
Abstract
The pressure pulsation of the mixed gas is the major reason to result in the abnormal stop of the generating equipments in a combined cycle power plant (CCPP) of a steel mill. An active control method for the attenuation of the pressure pulsation in large-flow mixed-gas pipe was presented. The pulsation mechanism of the mixed-gas pressure was discussed. A series of active control valves and error sensors were located along the mixed gas pipe. The results show that the secondary pressure pulsations produced by the active control valves can counteract the primary pressure pulsations of the mixed gas effectively. The pulsation amplitude of the mixed-gas pressure is limited in the required range for the CCPP. The proposed control approach is shown to be valuable in the engineering.
Keywords
milling; pipelines; power plants; pressure control; active control; combined cycle power plant; large-flow mixed gas pipe; pressure pulsation; pulsation amplitude; steel mill; Attenuation; Equations; Impellers; Milling machines; Power generation; Pressure control; Shafts; Steel; Turbines; Valves; CCPP; active control; mixed gas; pressure pulsation mechanism;
fLanguage
English
Publisher
ieee
Conference_Titel
Automation and Logistics, 2009. ICAL '09. IEEE International Conference on
Conference_Location
Shenyang
Print_ISBN
978-1-4244-4794-7
Electronic_ISBN
978-1-4244-4795-4
Type
conf
DOI
10.1109/ICAL.2009.5262683
Filename
5262683
Link To Document