Abstract :
The relationships between wafer size, wheel batch size, wheel radius, wafer packing fraction and ion beam width are explored for batch implanters designs for 150, 200 and 300 mm wafers. Analytical expressions for geometrical factors such as the scanned area fraction, the ratio of the area of Si wafers implanted to the scanned area, are derived for several batch and serial implanter geometry. The impact on the matching of process and transfer lot batch sizes on the dummy loading factors is also analysed
Keywords :
batch processing (industrial); ion implantation; 150 mm; 200 mm; 300 mm; Si; batch implanter; dummy loading factor; geometrical factor; ion beam width; process lot; productivity; scanned area; serial implanter; transfer lot; wafer packing fraction; wafer size; wheel batch size; wheel radius; Batch production systems; Educational institutions; Geometry; Implants; Ion beams; Mathematics; Productivity; Spinning; Throughput; Wheels;