• DocumentCode
    3486421
  • Title

    Selective focusing through inhomogeneous media: the DORT method

  • Author

    Prada, Claire ; Fink, Mathias

  • Author_Institution
    Lab. Ondes et Acoust., Paris VII Univ., France
  • Volume
    2
  • fYear
    1995
  • fDate
    7-10 Nov 1995
  • Firstpage
    1449
  • Abstract
    The DORT method (Decomposition de l´Operateur de Retournement Temporel) applies to ultrasonic detection and focusing with arrays of transducers. It is a signal analysis method based on the invariance of ultrasonic propagation under time reversal. It requires the measurement of the inter element impulse responses of the the propagating medium for all pair of elements in the array. A hermitian matrix called the time reversal operator is deduced from these responses and diagonalized. The eigenvectors are then used to perform selective focusing. This method is applied here to phase aberration correction. Experiments with weakly and strongly aberrating medium are shown
  • Keywords
    biomedical ultrasonics; ultrasonic focusing; ultrasonic propagation; DORT method; eigenvectors; hermitian matrix; inhomogeneous media; inter element impulse responses measurement; phase aberration correction; propagating medium; selective focusing; strongly aberrating medium; time reversal operator; transducers array; ultrasonic detection; ultrasonic focusing; weakly aberrating medium; Acoustic signal detection; Acoustic transducers; Nonhomogeneous media; Scattering; Signal analysis; Signal processing; Symmetric matrices; Ultrasonic transducer arrays; Ultrasonic transducers; Ultrasonic variables measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 1995. Proceedings., 1995 IEEE
  • Conference_Location
    Seattle, WA
  • ISSN
    1051-0117
  • Print_ISBN
    0-7803-2940-6
  • Type

    conf

  • DOI
    10.1109/ULTSYM.1995.495829
  • Filename