DocumentCode
3486777
Title
The establishment of power/energy standard at China Electric Power Research Institute and its comparison with NRC
Author
Bai, Jingfen ; Yang, Lin ; Zhao, Sha ; Zong, Jianhua ; So, Eddy
Author_Institution
CEPRI (China Electr. Power Res. Inst.), Beijing, China
fYear
2010
fDate
13-18 June 2010
Firstpage
275
Lastpage
276
Abstract
This paper describes the establishment of a single-phase power/energy standard at CEPRI. It is based on a computer-controlled commercial version of a NRC developed current-comparator-based power/energy bridge. The bridge allows the calibration of single-phase active/reactive power and energy meters at voltages up to 600 V, currents up to 100 A, any power factor from zero lag through unity to zero lead, and test frequencies of 45 Hz to 65 Hz. It has an estimated uncertainty (k=2) of less than 25 μW/VA. A comparison of power/energy meter calibration systems between China Electric Power Research Institute and the National Research Council of Canada will also be presented and discussed.
Keywords
bridge circuits; calibration; comparators (circuits); power factor; power meters; reactive power; China Electric Power Research Institute; National Research Council of Canada; current-comparator-based power bridge; energy meter calibration systems; frequency 45 Hz to 65 Hz; power factor; power meter calibration systems; reactive power; single phase power-energy standard; single-phase active power; test frequency; Bridge circuits; Calibration; Capacitors; Frequency estimation; Measurement standards; Reactive power; Standards development; System testing; Voltage; Watthour meters;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location
Daejeon
Print_ISBN
978-1-4244-6795-2
Type
conf
DOI
10.1109/CPEM.2010.5544814
Filename
5544814