• DocumentCode
    3486777
  • Title

    The establishment of power/energy standard at China Electric Power Research Institute and its comparison with NRC

  • Author

    Bai, Jingfen ; Yang, Lin ; Zhao, Sha ; Zong, Jianhua ; So, Eddy

  • Author_Institution
    CEPRI (China Electr. Power Res. Inst.), Beijing, China
  • fYear
    2010
  • fDate
    13-18 June 2010
  • Firstpage
    275
  • Lastpage
    276
  • Abstract
    This paper describes the establishment of a single-phase power/energy standard at CEPRI. It is based on a computer-controlled commercial version of a NRC developed current-comparator-based power/energy bridge. The bridge allows the calibration of single-phase active/reactive power and energy meters at voltages up to 600 V, currents up to 100 A, any power factor from zero lag through unity to zero lead, and test frequencies of 45 Hz to 65 Hz. It has an estimated uncertainty (k=2) of less than 25 μW/VA. A comparison of power/energy meter calibration systems between China Electric Power Research Institute and the National Research Council of Canada will also be presented and discussed.
  • Keywords
    bridge circuits; calibration; comparators (circuits); power factor; power meters; reactive power; China Electric Power Research Institute; National Research Council of Canada; current-comparator-based power bridge; energy meter calibration systems; frequency 45 Hz to 65 Hz; power factor; power meter calibration systems; reactive power; single phase power-energy standard; single-phase active power; test frequency; Bridge circuits; Calibration; Capacitors; Frequency estimation; Measurement standards; Reactive power; Standards development; System testing; Voltage; Watthour meters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2010 Conference on
  • Conference_Location
    Daejeon
  • Print_ISBN
    978-1-4244-6795-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2010.5544814
  • Filename