• DocumentCode
    3487337
  • Title

    Development of precision DC high voltage dividers

  • Author

    Li, Y.

  • Author_Institution
    Nat. Meas. Inst., Australia, Lindfield, NSW, Australia
  • fYear
    2010
  • fDate
    13-18 June 2010
  • Firstpage
    569
  • Lastpage
    570
  • Abstract
    Precision DC voltage dividers with ratings up to 1000 kV have been built using the 150 kV resistor module developed at the National Measurement Institute, Australia (NMIA). The structure of the 150 kV resistor module and the measurement techniques for evaluating its performance are described. The method for evaluating voltage ratio errors at voltages up to 1000 kV is discussed. It is shown that a ratio error of less than 5 μV/V at 150 kV and less than 100 μV/V at 1000 kV can be achieved.
  • Keywords
    resistors; voltage dividers; voltage measurement; measurement techniques; precision DC high voltage dividers; resistor module; voltage 150 kV; voltage ratio error evaluation; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2010 Conference on
  • Conference_Location
    Daejeon
  • Print_ISBN
    978-1-4244-6795-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2010.5544845
  • Filename
    5544845