DocumentCode
3487618
Title
AC/DC converter with medium frequency link for railway traction application. Evaluation of semiconductor losses and operating limits.
Author
Casarin, Jérémy ; Ladoux, Philippe ; Martin, Jérémy ; Chauchat, Bertrand
Author_Institution
ALSTOM Transp. (PRIMES), Séméac, France
fYear
2010
fDate
14-16 June 2010
Firstpage
1706
Lastpage
1711
Abstract
Nowadays, the typical railway traction chain, which operates under AC power supplies, includes a bulky and heavy transformer. In order to reduce the weight and the size of the input transformer, a medium frequency topology, which involves switches in soft commutation mode, is proposed. A test bench, based on one elementary stage of the complete structure, was built. It allows characterizing 6.5 kV IGBT modules in soft switching conditions. Switching losses measurements are performed to determine the optimal switching frequency and the operating limits of the converter.
Keywords
AC-DC power convertors; frequency convertors; insulated gate bipolar transistors; power semiconductor devices; power transformers; railway electrification; traction power supplies; AC power supplies; AC-DC converter; IGBT modules; medium frequency link; medium frequency topology; optimal switching frequency; railway traction application; railway traction chain; semiconductor losses; soft commutation switches; soft switching losses measurement; DC-DC power converters; Frequency conversion; Frequency measurement; Insulated gate bipolar transistors; Power semiconductor switches; Rail transportation; Switching loss; Testing; Topology; Traction power supplies; Power electronics; Power semiconductor switches; Rail transportation electronics;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Electrical Drives Automation and Motion (SPEEDAM), 2010 International Symposium on
Conference_Location
Pisa
Print_ISBN
978-1-4244-4986-6
Electronic_ISBN
978-1-4244-7919-1
Type
conf
DOI
10.1109/SPEEDAM.2010.5544860
Filename
5544860
Link To Document