DocumentCode :
3488458
Title :
Nonlinear post-beamforming filtering of pulse-echo ultrasound for contrast enhancement
Author :
Ebbini, Emad S.
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Minnesota Twin Cities, Minneapolis, MN, USA
fYear :
2009
fDate :
7-10 Nov. 2009
Firstpage :
2641
Lastpage :
2644
Abstract :
We have recently validated the use of a second-order Volterra (SoVF) model for separating the linear and quadratic components of the beamformed radio frequency (RF) data in pulse-echo ultrasonic imaging. The quadratic component captures the second order nonlinearities in the echo data. Grayscale images from the quadratic component, referred to as quadratic B-mode (QB-mode) images, typically have higher contrast and increased dynamic range than the standard B-mode images (without loss in spatial resolution). An SVD-based algorithm for finding the coefficients of the SoVF based on a linear plus quadratic prediction model of the RF data was developed and validated in a variety of imaging situations, including in vivo. This approach, while successful, may produce images with ripple artifacts due to the truncation of the kernel. Adaptive SoVF implementations based on both LMS and RLS methods have been developed and are shown to produce artifact-free QB-mode images using relatively small kernels, i.e. well suited for real-time implementation. In this paper, we show results of imaging microbubble ultrasound contrast agents (UCAs) to demonstrate the increased sensitivity and specificity of QB-mode imaging compared to conventional methods.
Keywords :
Volterra equations; array signal processing; filtering theory; image colour analysis; image enhancement; QB-mode images; contrast enhancement; grayscale images; imaging microbubble ultrasound contrast agents; nonlinear post-beamforming filtering; pulse-echo ultrasonic imaging; pulse-echo ultrasound; quadratic B-mode images; quadratic component; radio frequency data; second-order Volterra model; Dynamic range; Filtering; Gray-scale; High-resolution imaging; In vivo; Kernel; Predictive models; Radio frequency; Spatial resolution; Ultrasonic imaging; Contrast Enhancement; Inverse Filtering; Pulse-echo ultrasound; Volterra Filters; beamforming;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Image Processing (ICIP), 2009 16th IEEE International Conference on
Conference_Location :
Cairo
ISSN :
1522-4880
Print_ISBN :
978-1-4244-5653-6
Electronic_ISBN :
1522-4880
Type :
conf
DOI :
10.1109/ICIP.2009.5414098
Filename :
5414098
Link To Document :
بازگشت