• DocumentCode
    348961
  • Title

    Improving calibration to ensure better correlation between different EMC test facilities

  • Author

    Archambeault, Bruce ; Brench, Colin E.

  • Author_Institution
    IBM Corp., Research Triangle Park, NC, USA
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    392
  • Abstract
    This paper discusses a series of measurements performed to investigate site to site variations in radiated emission levels. After the data were examined a series of corrections were made to help account for the observed variations. This permits emission levels to be more realistically compared without excessive concern about where the testing was carried out
  • Keywords
    calibration; electromagnetic compatibility; test facilities; EMC test facilities; calibration; corrections; radiated emission levels; site to site variations; Antenna measurements; Calibration; Electromagnetic compatibility; Laboratories; Measurement uncertainty; Performance evaluation; Receiving antennas; Reflection; Test facilities; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1999 IEEE International Symposium on
  • Conference_Location
    Seattle, WA
  • Print_ISBN
    0-7803-5057-X
  • Type

    conf

  • DOI
    10.1109/ISEMC.1999.812935
  • Filename
    812935