• DocumentCode
    3491652
  • Title

    Comparison of series and shunt active filter approaches for high-performance magnet load applications

  • Author

    Jin, H. ; Joos, Geza

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Concordia Univ., Montreal, Que., Canada
  • Volume
    2
  • fYear
    1995
  • fDate
    5-8 Sep 1995
  • Firstpage
    862
  • Abstract
    The performance of magnet power supplies can be enhanced by using a combination of a thyristor rectifier and a PWM converter. The PWM converter, which can be connected in series or in parallel with the rectifier, functions as an active filter to cancel the effect of rectifier harmonics under transient conditions, it can also correct tracking errors. In this paper, the basic operating principles, control schemes, and differences in the series and shunt connected systems are discussed. The component sizes, power ratings, and the complexity of these two topologies are compared
  • Keywords
    PWM power convertors; active filters; electromagnets; power supplies to apparatus; power system harmonics; rectifying circuits; thyristor convertors; transients; PWM converter; control schemes; high-performance magnet load; operating principles; power ratings; rectifier harmonics cancellation; series active filter; shunt active filter; thyristor rectifier; tracking errors correction; transient conditions; Active filters; Control systems; Error correction; Magnetic separation; Power harmonic filters; Power supplies; Pulse width modulation converters; Rectifiers; Thyristors; Topology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Computer Engineering, 1995. Canadian Conference on
  • Conference_Location
    Montreal, Que.
  • ISSN
    0840-7789
  • Print_ISBN
    0-7803-2766-7
  • Type

    conf

  • DOI
    10.1109/CCECE.1995.526563
  • Filename
    526563