• DocumentCode
    3495683
  • Title

    The rheometer with vibrator driven by white noise

  • Author

    Pinzhong, Dai ; Yuan, Tian

  • Author_Institution
    Tianjin Univ., China
  • fYear
    1988
  • fDate
    4-7 Nov. 1988
  • Firstpage
    808
  • Abstract
    In a previous study (Biomechanics Symposium, 1985), the authors designed a heavy electromagnetic system with a laser displacement detector for identifying the viscoelasticity of biofluids, but there was no mathematic model expressing the relation between motion style and rheologic parameter of the fluid. Using the concepts of complex viscosity and combining the frequency response characteristic of the system, the authors propose a novel rheometer which utilizes a white noise signal to drive a linear second-order vibrator. They present the relation between the rheologic properties of the fluid and the white-noise response of the system. The experimental results are basically in agreement with previous results.<>
  • Keywords
    biological techniques and instruments; biorheology; biorheology; complex viscosity; frequency response characteristic; linear second-order vibrator; rheologic properties; rheometer; white noise;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1988. Proceedings of the Annual International Conference of the IEEE
  • Conference_Location
    New Orleans, LA, USA
  • Print_ISBN
    0-7803-0785-2
  • Type

    conf

  • DOI
    10.1109/IEMBS.1988.95061
  • Filename
    95061