DocumentCode :
3496803
Title :
A novel optimized LCL-filter designing method for grid connected converter
Author :
Zeng, Guohong ; Rasmussen, Tonny W. ; Teodorescu, Remus
Author_Institution :
Sch. of Electr. Eng., Beijing Jiaotong Univ., Beijing, China
fYear :
2010
fDate :
16-18 June 2010
Firstpage :
802
Lastpage :
805
Abstract :
This paper presents a new LCL-filters optimized designing method for grid connected voltage source converter. This method is based on the analysis of converter output voltage components and inherent relations among LCL-filter parameters. By introducing an optimizing index of equivalent total capacity of all filter components, with clear physical meaning of minimum cost and volume, a set of optimal values of attenuation ratio and inductance-split-ratio is obtained for deciding all LCL-filter parameters. With this method, filter overall capacity can be minimized while the grid limit of switching frequency distortion is fulfilled. Compared to the existing methods, the proposed method contains only four steps without try-and-error process, so it is efficient and easy to implement. Simulation results of a 50kVA grid-connected inverter with two sets of LCL-filter parameters under different optimizing condition are presented to verify the reasonability and feasibility of the method.
Keywords :
Capacitors; Converters; Harmonic analysis; Inductance; Inverters; Power harmonic filters; Switching frequency; LCL-filter; grid connected inverter; optimized design; voltage source converter;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics for Distributed Generation Systems (PEDG), 2010 2nd IEEE International Symposium on
Conference_Location :
Hefei, China
Print_ISBN :
978-1-4244-5669-7
Type :
conf
DOI :
10.1109/PEDG.2010.5545882
Filename :
5545882