• DocumentCode
    3498044
  • Title

    Enhancing partial discharge measurement with extended resolution analyser

  • Author

    Kumar, S. Senthil ; Narayanachar, M.N. ; Nema, R.S.

  • Author_Institution
    Dept. of High Voltage Eng., Indian Inst. of Sci., Bangalore, India
  • Volume
    5
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    200
  • Abstract
    Partial discharge fingerprints are generally obtained for model samples with known defects with computer-aided partial discharge analysers. These fingerprints help in generating a database for classification of PD defects. Due to differences in PD detector characteristics, the measurements can be different with different PD detectors. The fingerprints obtained then, are dependent on the characteristics of PD detectors and the fingerprints obtained may lead to wrong classification and interpretation. The paper proposes a solution of parallel detector scheme which will help obtain standard fingerprints independent of the PD detector characteristics
  • Keywords
    partial discharge measurement; PD defects classification database; PD detector characteristics; computer-aided partial discharge analysers; extended resolution analyser; measurement errors; parallel detector scheme; partial discharge measurement enhancement; pulses measurement;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
  • Conference_Location
    London
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-719-5
  • Type

    conf

  • DOI
    10.1049/cp:19990920
  • Filename
    818272