DocumentCode :
3498276
Title :
Laboratory characterization of electromechanical behaviour of Bessel array-transducer annuli for detection & imaging in biological media
Author :
Castellanos, L. ; Ramos, A. ; Calás, H. ; Eiras, J.A. ; Moreno, E.
Author_Institution :
Inst. of Acoust., Ultrasonic Signals, Syst. & Technol., Videus-Lab., CSIC, Madrid, Spain
fYear :
2011
fDate :
March 28 2011-April 1 2011
Firstpage :
359
Lastpage :
364
Abstract :
X wave annular arrays, properly driven, could be extensively applied for medical imaging and detection. The main utility of such a device is to permit the achieving of good collimation in the ultrasonic beam maintained along certain depth. In order to generate these kinds of waves, it is necessary to precisely excite a radiating aperture in a Bessel-transducer way. The work aim is the characterization of the behavior of array annuli in a 2 MHz piezoelectric Bessel transducer. The analysis, in function of the frequency, of a basic electrical characterization, measuring the electrical complex admittance and the cross-coupling of the array elements, as well as the evaluation of the annuli emission impulse responses, are performed by employing an installation of own design (Videus-CSIC lab), reciently developed for: pulsed acoustic signals acquisition, efficient array driving and advanced processing. Knowing the response of each one of elements in this type of array, it is already possible the achieving of a correct design of the especial multichannel pulsed electrical driving needed to generate limited diffraction X-waves applicable in medicine.
Keywords :
biomedical transducers; biomedical ultrasonics; data acquisition; electric impedance measurement; electromechanical effects; medical image processing; medical signal detection; piezoelectric transducers; ultrasonic transducer arrays; Bessel array transducer annuli; X wave annular arrays; advanced processing; annuli emission impulse responses; array driving; biological media; collimation; electrical complex admittance; electromechanical behaviour; medical detection; medical imaging; multichannel pulsed electrical driving; piezoelectric Bessel transducer; pulsed acoustic signal acquisition; radiating aperture; ultrasonic beam; Acoustic arrays; Acoustics; Couplings; Frequency measurement; Medical services; Sonar equipment; Annular arrays; Bessel transducer; Cross-coupling; Electromechanical behavior; Emission impulse response;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Health Care Exchanges (PAHCE), 2011 Pan American
Conference_Location :
Rio de Janeiro
Print_ISBN :
978-1-61284-915-7
Type :
conf
DOI :
10.1109/PAHCE.2011.5871926
Filename :
5871926
Link To Document :
بازگشت