• DocumentCode
    3498607
  • Title

    Detecting delaminated stator winding insulation using the ramped high-voltage DC test method

  • Author

    Rux, L.M. ; Grzybowski, S.

  • Author_Institution
    Dept. of Interior, Bur. of Reclamation, Denver, CO, USA
  • Volume
    5
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    331
  • Abstract
    High-voltage DC tests have traditionally been used to detect cracks and fissures, surface contamination, and moisture in rotating machine insulation systems. Not generally recognized, however, is the ability of DC testing to diagnose delaminated groundwall insulation. This impaired insulation condition is generally evaluated using AC tests, such as dissipation factor tip up and partial discharge measurements. In this paper, the ramped high voltage DC test method is described, and its ability to detect and monitor delaminated stator winding insulation is demonstrated. Supporting field data are presented and analyzed
  • Keywords
    machine insulation; capacitance measurement; crack detection; delaminated groundwall insulation; delaminated stator winding insulation detection; dissipation factor tip up; fissures detection; impaired insulation condition; moisture detection; partial discharge measurements; ramped high voltage DC test method; ramped high-voltage DC test method; rotating machine insulation; surface contamination detection;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
  • Conference_Location
    London
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-719-5
  • Type

    conf

  • DOI
    10.1049/cp:19990952
  • Filename
    818304