DocumentCode
3498607
Title
Detecting delaminated stator winding insulation using the ramped high-voltage DC test method
Author
Rux, L.M. ; Grzybowski, S.
Author_Institution
Dept. of Interior, Bur. of Reclamation, Denver, CO, USA
Volume
5
fYear
1999
fDate
1999
Firstpage
331
Abstract
High-voltage DC tests have traditionally been used to detect cracks and fissures, surface contamination, and moisture in rotating machine insulation systems. Not generally recognized, however, is the ability of DC testing to diagnose delaminated groundwall insulation. This impaired insulation condition is generally evaluated using AC tests, such as dissipation factor tip up and partial discharge measurements. In this paper, the ramped high voltage DC test method is described, and its ability to detect and monitor delaminated stator winding insulation is demonstrated. Supporting field data are presented and analyzed
Keywords
machine insulation; capacitance measurement; crack detection; delaminated groundwall insulation; delaminated stator winding insulation detection; dissipation factor tip up; fissures detection; impaired insulation condition; moisture detection; partial discharge measurements; ramped high voltage DC test method; ramped high-voltage DC test method; rotating machine insulation; surface contamination detection;
fLanguage
English
Publisher
iet
Conference_Titel
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location
London
ISSN
0537-9989
Print_ISBN
0-85296-719-5
Type
conf
DOI
10.1049/cp:19990952
Filename
818304
Link To Document