• DocumentCode
    3498895
  • Title

    New approach to high voltage electrodynamic drum separator. II. Experimental verification

  • Author

    Ciesla, Antoni

  • Author_Institution
    Electr. Power Inst., Univ. of Min. & Metall., Cracow, Poland
  • Volume
    5
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    406
  • Abstract
    One kind of electroseparation is the conductance method, which depends on differences in charge vs time characteristic. Separated components are of different electric conductances and consequently, of various time constants of charging. Prevalent construction of the device is the “corona” drum separator (Huffs invention). This paper follows the theoretical analysis of the author (see Proc. ISH, London, 1999). The drum separator is considered as a control object. Some experimental results are given and analysed
  • Keywords
    electrodynamics; conductance method; control object; corona drum separator; electroseparation; high voltage electrodynamic drum separator; separated components;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
  • Conference_Location
    London
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-719-5
  • Type

    conf

  • DOI
    10.1049/cp:19990968
  • Filename
    818320