DocumentCode
3500078
Title
2-Dimensional near-field millimeter-wave scanning with micromachined probe for skin cancer diagnosis
Author
Topfer, F. ; Dudorov, S. ; Oberhammer, Joachim
Author_Institution
KTH R. Inst. of Technol., Stockholm, Sweden
fYear
2013
fDate
20-24 Jan. 2013
Firstpage
1057
Lastpage
1060
Abstract
This paper reports for the first time on the 2-dimensional scanning performance of a micromachined millimeter-wave (100 GHz) near-field probe with a substantially reduced tip size which is designed for skin cancer diagnosis. Furthermore, it introduces a novel concept of creating inhomogeneous test samples with tailor-made and locally altered permittivity which mimick skin tissue with small anomalies and are used for characterizing the probe. A probe prototype with a tip size of 300 × 600 μm2 and test samples with permittivity in the range of cancerous and healthy skin tissue were fabricated by micromachining and used for evaluating the sensitivity and resolution of the probe. This paper reports for the first time on 2-dimensional scanning performance, resolution, repeatability, long-term stability, and sensitivity, which are important for qualifying such measurement probes for medical applications. The resolution of the prototype, which is important for early detection of small tumor speckles, was found to be better than 200 μm, i.e. 1/6 of the medium-normalized wavelength. The reproducibility of the probe setup including operator uncertainty is 1.36% (1σ) and the long term stability of reference measurements is 0.59% (1σ) over 8 hours.
Keywords
biomedical measurement; cancer; micromachining; millimetre waves; patient diagnosis; permittivity; sensitivity; skin; tumours; 2-dimensional near-field millimeter-wave scanning; cancerous skin tissue; frequency 100 GHz; healthy skin tissue; inhomogeneous test samples; locally altered permittivity; long-term stability; measurement probes; medical applications; medium-normalized wavelength; micromachined millimeter-wave near-field probe; probe prototype; sensitivity; skin cancer diagnosis; substantially reduced tip size; tumor speckles; Microwave measurements; Permittivity; Permittivity measurement; Probes; Reflection; Skin cancer;
fLanguage
English
Publisher
ieee
Conference_Titel
Micro Electro Mechanical Systems (MEMS), 2013 IEEE 26th International Conference on
Conference_Location
Taipei
ISSN
1084-6999
Print_ISBN
978-1-4673-5654-1
Type
conf
DOI
10.1109/MEMSYS.2013.6474431
Filename
6474431