DocumentCode :
350140
Title :
Laboratory-relevant corona inception of a 1-m-airgap under impulse voltage
Author :
Rühling, F. ; Heilbronner, F. ; Díaz, R.R. ; Ortéga, P.
Author_Institution :
Inst. of High Voltage Eng. & Electr. Power Transmission, Tech. Univ. Munchen, Germany
Volume :
3
fYear :
1999
fDate :
1999
Firstpage :
39
Abstract :
The corona inception voltage of a point-plane airgap is studied in a climatic chamber under various test conditions: polarity of the (1-cosine) impulse voltage, humidity, artificially generated positive and negative ions, agitated air in the laboratory and various electrode materials. The lowest inception voltages are obtained, when the electrode is not treated, the laboratory´s air is not agitated, negative polarity is applied, humidity is high and negative ions are generated artificially. Under these conditions, the measured inception voltages reach minimum values and their statistical spread is reduced significantly
Keywords :
air gaps; 1 m; agitated air; artificially generated negative ions; artificially generated positive ions; corona inception voltage; electrode materials; humidity; impulse voltage; lowest inception voltages; point-plane airgap; test conditions;
fLanguage :
English
Publisher :
iet
Conference_Titel :
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location :
London
ISSN :
0537-9989
Print_ISBN :
0-85296-719-5
Type :
conf
DOI :
10.1049/cp:19990694