DocumentCode
350204
Title
Humidity correction effects on AC sparkover voltage characteristics of small air gaps
Author
Sebo, Stephen A. ; Pawlak, Christopher M. ; Owiecinski, D.S. ; Que, Weiguo
Author_Institution
Dept. of Electr. Eng., Ohio State Univ., Columbus, OH, USA
Volume
3
fYear
1999
fDate
1999
Firstpage
325
Abstract
The main focus of this paper is the discussion of differences between the two calculation methods of humidity correction factors provided by the 1978 and 1995 versions of the IEEE Standard Techniques for High Voltage Testing (IEEE Std. 4). Tabulated values of the “new” humidity correction factor and the reciprocal value of the “old” humidity factor are given at the end of the paper
Keywords
air gaps; AC sparkover voltage characteristics; IEEE Standard Techniques for High Voltage Testing; IEEE Std. 4; humidity correction effects; small air gaps;
fLanguage
English
Publisher
iet
Conference_Titel
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location
London
ISSN
0537-9989
Print_ISBN
0-85296-719-5
Type
conf
DOI
10.1049/cp:19990765
Filename
816786