    The major differences between symmetrical topology magamps and the forward power converter magamp are discussed. In a forward power converter, a small portion of the magnetizing current of the power transformer is diverted to the secondary for reset of the magamp´s saturable reactor. In symmetrical topologies, the transformer´s magnetizing current is not used for reset of the saturable reactor(s). The magnetizing current shifts to the secondary where it causes a series of problems. The authors examine these problems, identify solutions, and explain why a half-bridge magamp power supply is inherently less versatile than the forward power converter
  • Keywords
    magnetic amplifiers; magnetisation; power convertors; power supplies to apparatus; power transformers; saturable core reactors; voltage control; voltage regulators; forward power converter; half-bridge; magamps; magnetic amplifiers; magnetizing current; post regulators; power supply; power transformer; saturable reactor; secondary; symmetrical topologies; voltage control; voltage regulators; Circuits; Diodes; Inductors; Power systems; Power transformers; Pulse transformers; Regulators; Switches; Topology; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 1991. APEC '91. Conference Proceedings, 1991., Sixth Annual
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-0024-6
  • Type

    conf

  • DOI
    10.1109/APEC.1991.146199
  • Filename
    146199