• DocumentCode
    3502823
  • Title

    Precision analysis of MED scene matching

  • Author

    Jun, Zliaiig ; Xiaomao, Liu ; Jixian, Zhaiig ; Jinwen, Tian ; Liu Jian ; Fuyuan, Peng

  • Author_Institution
    Dept. of Electron & Inf. Eng., Huazhong Univ. of Sci. & Technol., Wuhan, China
  • Volume
    2
  • fYear
    1996
  • fDate
    14-18 Oct 1996
  • Firstpage
    958
  • Abstract
    The standard variance of the location error is defined as the precision estimation of scene matching and the precision analysis of scene matching by the method of MED (minimum entropy difference) is achieved under the condition that the real-time image is composed of original image and additional noise. The conclusion we obtain is helpful for the selection of scene matching ranges and scene matching algorithms, and the quantitative evaluation of scene matching of real-time and reference images
  • Keywords
    image matching; minimum entropy methods; noise; MED scene matching; location error; minimum entropy difference; noise; precision analysis; real-time images; scene matching algorithms; scene matching ranges; standard variance; Entropy; Gaussian noise; Gaussian processes; Geometry; Image analysis; Image processing; Layout; Length measurement; Noise measurement; White noise;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Signal Processing, 1996., 3rd International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    0-7803-2912-0
  • Type

    conf

  • DOI
    10.1109/ICSIGP.1996.566249
  • Filename
    566249