DocumentCode
3504897
Title
Electrical performance of 115 kV transmission lines fiberglass crossarms aged in field
Author
Grzybowski, S.
Author_Institution
Dept. of Electr. & Comput. Eng., Mississippi State Univ., MS, USA
Volume
2
fYear
1997
fDate
25 -30 May 1997
Firstpage
774
Abstract
This paper presents the results of an investigation on the ac voltage and lightning impulse performance of 115 kV transmission lines fiberglass crossarms aged in the field. The crossarms removed after 10-20 years from service, crossarms stored outdoors but not in service and new crossarms were examined. The evaluation of electrical performance was based on flashover voltage value at standard lightning impulse voltage and the ac flashover voltage. The CFO voltages for lightning impulses were measured under dry and wet conditions, and the tests were conducted with positive and negative polarity. The obtained flashover voltages show some differences in electrical strength of fiberglass crossarms removed from service
Keywords
ageing; electric strength; flashover; insulators; power transmission lines; 115 kV; AC voltage; critical flashover voltage; electrical strength; fiberglass crossarm; field ageing; lightning impulse; outdoor insulator; transmission line; Aging; Flashover; Lightning; Optical fiber testing; Plastic insulation; Polymers; Porcelain; Power transmission lines; Transmission lines; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Properties and Applications of Dielectric Materials, 1997., Proceedings of the 5th International Conference on
Conference_Location
Seoul
Print_ISBN
0-7803-2651-2
Type
conf
DOI
10.1109/ICPADM.1997.616550
Filename
616550